: Once configured (Static or DHCP), turn all DIP switches OFF and apply settings to reboot. Key Specifications Power Requirements : 12 VDC ±plus or minus 10% at approximately 300 mA. Communication Ports : Primary : Onboard Ethernet for host communication.
: All boards in a single M5 or M3000 controller must be converted to Lenel M Series; you cannot mix legacy CASI M Series boards with Lenel M Series boards in the same enclosure. LNL-3300-M5 lenel lnl3300m5 installation manual upd top
Ensure correct polarity. Reversing the positive and negative leads can permanently damage the controller. Downstream Communication (RS-485) : Once configured (Static or DHCP), turn all
Each UPD device needs a unique hardware address (1-127). Use binary DIP switches: : All boards in a single M5 or
Use shielded twisted pair for readers (Belden 9535 or equivalent). Shield ties to ground at controller only.